Versatile standard flowmeter for the water and wastewater industry
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss
Flexible engineering – sensor with fixed or lap-joint process connections
Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
Improved plant availability – sensor compliant with industry-specific requirements
Safe operation – no need to open the device
Time-saving local operation without additional software and hardware – integrated web server
Integrated verification and build-up detection – Heartbeat Technology
With its international approvals for custody transfer as well as drinking water, Promag W serves the broadest variety of applications. It is available as both compact or remote version. Promag W 400 saves time and costs thanks to the broad functionality of its transmitter optimized for Water, Wastewater & Waste. In addition, Heartbeat Technology enables measurement reliability and compliant verification.
- The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
- Ideal for water measurement , e.g. drinking water, utility water and industrial/municipal wastewater
- International drinking water approvals
- Degree of protection IP68 (Type 6P enclosure)
- Approved for custody transfer to MI-001/OIML R49
- Transmitter housing made of durable polycarbonate or aluminium
- WLAN access
- Integrated data logger: measured values monitoring
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
Ideal for water measurement, e.g. drinking water, utility water and industrial/municipal wastewater.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). Approved for custody transfer to MI-001/OIML R49.
Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring.
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
DN 25 to 3000 (1 to 78"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish
according to EN ISO 12944 C5‐M/Im1/Im2/Im3
Transmitter remote version: IP66/67, Type 4X enclosure
Configuration via local display, web browser and operating tools possible
0‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency output (passive)
Switch output (passive)
Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run)
Related Products
Zalo: Click here
Whatsapp: 0981272824
Zalo: Click here