Valmet Portable Conductivity and Concentration Measurement 3000
  • Rechargeable industrial meters for measuring process liquids from ultrapure water to hazardous acids.
  • Rugged and portable meter for lab and on-site sampling, calibration or verification.
  • Traceable conductivity and temperature calibration certificates and annual calibration service are available on request.
Like
Share
  • Description
  • Special Features
  • Technical Specifications
  • Downloads
  • Description
  • Special Features
  • Technical Specifications
  • Downloads
Description

Conductivity and concentration measurement on the go

Valmet portable meters are practical and handy for making precise laboratory measurements or collecting accurate reference measurements to optimize in-line measurement installations.

Build confidence in your process

The Valmet Portable Conductivity and Concentration Measurement 3000 series of rechargeable industrial meters are suitable for measuring process liquids from ultrapure water to hazardous acids.

Rugged, yet easy to carry, you can use the meter for lab and on-site sampling, calibration or verification. The 3001 model is exclusively for conductivity, with two setup modes for ultrapure water (UPW) and two for standard water. For concentration measurement, we offer the 3003 model which features two setup modes for concentration and two for conductivity.

Traceable conductivity and temperature calibration certificates are available on request. If needed, Valmet can adjust the testing conditions to meet customer-specific requirements. We also provide an annual calibration service.

Measure anywhere with ease

The analyzer unit is housed in an aluminum case with a swiveling handle for carrying and serving as a stand. All sensors are based on the 4-electrode principle which eliminates errors from the polarization effect on the electrode surface.

Sensors are also completely interchangeable. You can swap sensors without sacrificing accuracy in conductivity or temperature. There is also no need for recalibration or re-entering the cell constant. In addition, each setup mode in the analyzer has a complete recipe and settings for output range and calibration.

Special Features

Concentration recipe table for 3003

Chemical Concentration range Temperature
Hydrogen fluoride (HF) 0-5% 0-50°C
Hydrogen fluoride (HF) 0-10% 0-50°C
Hydrogen fluoride (HF) 0-70% 0-70°C
Hydrogen fluoride (HF) 99.0-100% 0-50°C
Hydrogen fluoride (HF) 99.7-100% 0-50°C
Water in Hydrogen fluoride (H2O@HF) 0-50 ppm 0-40°C
Water in Hydrogen fluoride (H2O@HF) 0-3000 ppm 0-50°C
Water in Hydrogen fluoride (H2O@HF) 0-1.5% 0-50°C
Sulfuric acid (H2SO4) 0-10% 0-100°C
Sulfuric acid (H2SO4) 0-20% 15-80°C
Sulfuric acid (H2SO4) 0-30% 10-50°C
Sulfuric acid (H2SO4) 35-50% 10-45°C
Sulfuric acid (H2SO4) 35-61% 0-50°C
Sulfuric acid (H2SO4) 45-80% 10-55°C
Sulfuric acid (H2SO4) 50-70% 20-85°C
Sulfuric acid (H2SO4) 50-80% 10-50°C
Sulfuric acid (H2SO4) 50-80% 25-60°C
Sulfuric acid (H2SO4) 72-82% 20-70°C
Sulfuric acid (H2SO4) 92-100% 20-70°C
Sulfuric acid (H2SO4) 93-100% 20-110°C
Sulfuric acid (H2SO4) 0-230 g/l 0-100°C
Hydrogen chloride (HCl) 0-15% 10-80°C
Hydrogen chloride (HCl) 25-40% 0-60°C
Hydrogen chloride (HCl) 30-36% 15-45°C
Nitric acid (HNO3) 0-20% 0-90°C
Nitric acid (HNO3) 0-25% 0-40°C
Nitric acid (HNO3) 45-77% 20-80°C
Nitric acid (HNO3) 50-75% 0-65°C
Potassium hydroxide (KOH) 0-10% 65-90°C
Potassium hydroxide (KOH) 0-24% 25-100°C
Potassium hydroxide (KOH) 20-30% 50-70°C
Sodium chloride (NaCl) 0-10% 0-100°C
Sodium chloride (NaCl) 0-200 g/l 0-100°C
Sodium chloride (NaCl) 150-300 g/l 0-100°C
Sodium chloride (NaCl) 0-327 g/l 20-100°C
Sodium hydroxide (NaOH) 0-10% 0-100°C
Sodium hydroxide (NaOH) 0-10% 0-130°C
Sodium hydroxide (NaOH) 0-15% 30-70°C
Sodium hydroxide (NaOH) 0-16% 60-90°C
Sodium hydroxide (NaOH) 18-35% 0-50°C
Sodium hydroxide (NaOH) 20-40% 20-50°C
Sodium hydroxide (NaOH) 45-55% 40-75°C
Sodium hydroxide (NaOH) 100-200 g/l 40-100°C
Phosphorus pentoxide (P2O5) 45-60% 20-80°C
Phosphorus pentoxide (P2O5) 50-70% 50-100°C
Salinity 0-42 ppt -2-35°C
Sulfur dioxide (SO2) 0-25 g/l 0-50°C
Sulfur dioxide (SO2) 0-60 g/l 0-35°C
Sulfur dioxide (SO2) 20-70 g/l 20-90°C
Sulfur trioxide/Oleum (SO3) 0-8% 20-80°C
Sulfur trioxide/Oleum (SO3) 18-34% 20-80°C
Sulfur trioxide/Oleum (SO3) 18-40% 20-80°C
Sulfur trioxide/Oleum (SO3) 18-40% 30-110°C
Sulfur trioxide/Oleum (SO3) 20-35% 30-110°C
Sulfur trioxide/Oleum (SO3) 20-40% 30-100°C
Sulfur trioxide/Oleum (SO3) 35-45% 20-60°C
Sulfur trioxide/Oleum (SO3) 55-70% 25-80°C
Technical Specifications
Conductivity range
55 nS/cm to 1000 mS/cm
Accuracy
± 0.25% (0.5% from 10 μS/cm to 0.055 μS/cm +2 ± 1 nS/cm)
Sampling rate
3 /sec.
Temperature range
-40 °C to +250 °C using sensor with built-in Pt 1000 4-wire interface
Temperature compensations for UPW, std. salt, lye, or acid
Protection class
IP 65/DIN EN 60529
Battery type
industrial LI-ion battery
Battery life
~150 hours without backlight, ~30 hours with backlight
Charging time
3 hours (mains), 5 hours (USB)
Charger
mini-USB or mains adapter (100–240 V ~ 50/60 Hz 5 VA 100 mA)
Dimensions
65 x 40 x 35 mm (weight: 0.1 kg)

Related Products

Sales Account Manager
Nguyen Minh Dung

Zalo: Click here

Sales Manager
John Dinh

Linked in: Click here

Zalo: Click here

Sales Account Manager
Pham Dang Dinh

Zalo: Click here

Solution Consulting

The leading symbol of belief in automation and engineering solutions for people and a reliable partner of all customers.

    Contact Us